Cathodic Protection Installation

Design, supply and installation of ICCP and sacrificial anode systems, tested and documented to international standards.

Corrosion quietly eats buried steel every day. However, a well-designed cathodic protection installation can stop it for decades.

PT Saka Nusa Persada designs, supplies and installs cathodic protection (CP) systems for pipelines, storage tanks, jetties and offshore structures across Indonesia. As a result, your assets get long-term, measurable protection rather than a one-off coating fix.

Cathodic protection installation on a buried pipeline by PT Saka Nusa Persada
Anode and cable installation in the field.

How CP Works

Cathodic protection turns the protected metal into the cathode of an electrochemical cell, so the corrosion reaction shifts away from your asset. In practice, we use two proven systems.

Impressed Current (ICCP)

An external power source drives current through MMO, graphite or cast iron anodes. Therefore, ICCP suits long pipelines, tank farms, jetties and offshore platforms.

Sacrificial Anodes (SACP)

Zinc, magnesium or aluminium anodes corrode in place of your structure. Because SACP needs no power supply, it suits buried pipelines, buried tanks and medium-sized structures.

Our Cathodic Protection Installation Scope

  • Survey and design: soil resistivity survey, current requirement calculation, anode layout and anode life estimation.
  • Material supply: MMO/Ti, graphite and cast iron anodes, Zn, Mg and Al anodes, transformer-rectifiers, junction boxes and test posts.
  • Installation: anode beds, cable routing and exothermic welding, test stations and rectifier setup, so the system is ready to energise.
  • Testing and commissioning: structure-to-soil potentials, depolarisation and interference testing, and current distribution analysis.
  • Documentation: as-built drawings, test results and maintenance recommendations for your integrity records.

Standards and Protection Criteria

We design and install every system in line with NACE/AMPP practice, ISO 15589, API 651 and ASTM G1 and G97. In addition, we tune each system to keep protection potentials within the −850 mV to −1,200 mV range. You can read more about corrosion control practice at AMPP.

Where We Apply Cathodic Protection Installation

  • Transmission and distribution pipelines
  • Aboveground and underground storage tanks
  • Offshore platforms and subsea structures
  • Jetties, sheet piles and marine ports
  • Utility systems such as fire water lines

Need the materials only? We also supply KIG TECH cathodic protection systems, while our CIPS and DCVG surveys verify existing systems.

Is your CP system still protecting the asset? Request a technical assessment, and then we will assess, design and install the right cathodic protection system.

Need this service?

Talk to Our Field Team

Tell us the location, line size and operating conditions. We will propose the right method and schedule.

Request a Quote

Let’s work together

Let’s talk about your next scope

Tell us the line, the service and the constraint, whether it is a shutdown window, access or budget. Then we will come back with the right technology, correctly sized, from the right principal.

Technical consultationProduct selection and sizing for your service conditions.
Proposal & documentationQuotation, datasheets and certificates for your procurement process.
Delivery & site supportLogistics to site, application support and after-sales follow-up.
More services

Explore Our Other Services

One team for prevention, reinforcement, connection and emergency response.